2013年7月31日星期三

mixing station failure

Valve failure are: pressure regulator is not high, or the slow pressure rise.
Pressure regulator is not high, often due to pressure regulator spring break or diaphragm failure and must be renewed; pressure rises slowly, usually caused because the filter is clogged, should be removed and washed.
Piping failures are: leaking pipe joints, stationary concrete batching plant, condensate aggregation.
Leaking pipe joints and hose rupture up to judge the sound leak from the site, should be promptly repaired or replaced; if there is accumulating condensate pipeline, it shall promptly drained, is characterized by condensed water in the northern winter, easy to knot Ice and clogging gas.
Compressed air processing components (triplets) faults are: oil and water separator failure, regulator and lubricator failure.
Failure of oil-water separator is divided into,precast concrete plant, breakage, drain valve moving parts moving parts is not flexible and so on. Work should always clean the filter, remove sewage and impurities inside the oil.
Regulator fault with the "valve failure" identical.
Lubricator fault phenomenon: no drop of oil deposited on the bottom of the oil cup water, oil cup seal failures. When the mist does not drip, check the inlet gas flow rate is below the fog flow, leaks, clogged fuel adjustment needle, etc.; if the oil cup bottom sediment moisture, should be immediately removed; when seal is damaged, should be replaced.